31 research outputs found

    X ray microscope assembly and alignment support and advanced x ray microscope design and analysis

    Get PDF
    Considerable efforts have been devoted recently to the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft x ray application in microscopy and projection lithography. The spherical Schwarzschild microscope consists of two concentric spherical mirrors configured such that the third order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for x ray applications, it is desirable to have only two reflecting surfaces in a microscope. In order to reduce microscope aberrations and increase the field of view, generalized mirror surface profiles have been considered in this investigation. Based on incoherent and sine wave modulation transfer function (MTF) calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical head reflecting two mirror microscope configurations

    Design and analysis of multilayer x ray/XUV microscope

    Get PDF
    The design and analysis of a large number of normal incidence multilayer x ray microscopes based on the spherical mirror Schwarzschild configuration is examined. Design equations for the spherical mirror Schwarzschild microscopes are summarized and used to evaluate mirror parameters for microscopes with magnifications ranging from 2 to 50x. Ray tracing and diffraction analyses are carried out for many microscope configurations to determine image resolution as a function of system parameters. The results are summarized in three publication included herein. A preliminary study of advanced reflecting microscope configurations, where aspherics are used in place of the spherical microscope mirror elements, has indicated that the aspherical elements will improve off-axis image resolution and increase the effective field of view

    X ray imaging microscope for cancer research

    Get PDF
    The NASA technology employed during the Stanford MSFC LLNL Rocket X Ray Spectroheliograph flight established that doubly reflecting, normal incidence multilayer optics can be designed, fabricated, and used for high resolution x ray imaging of the Sun. Technology developed as part of the MSFC X Ray Microscope program, showed that high quality, high resolution multilayer x ray imaging microscopes are feasible. Using technology developed at Stanford University and at the DOE Lawrence Livermore National Laboratory (LLNL), Troy W. Barbee, Jr. has fabricated multilayer coatings with near theoretical reflectivities and perfect bandpass matching for a new rocket borne solar observatory, the Multi-Spectral Solar Telescope Array (MSSTA). Advanced Flow Polishing has provided multilayer mirror substrates with sub-angstrom (rms) smoothnesss for the astronomical x ray telescopes and x ray microscopes. The combination of these important technological advancements has paved the way for the development of a Water Window Imaging X Ray Microscope for cancer research

    Anti-TNF-α antibody allows healing of joint damage in polyarthritic transgenic mice

    Get PDF
    Anti-tumor-necrosis-factor-α (TNF-α) monoclonal antibody was used to treat Tg197 transgenic mice, which constitutively produce human TNF-α (hTNF-α) and develop a progressive polyarthritic disease. Treatment of both young (7- or 8-week-old) and aged (27- or 28-week-old) mice commenced when at least two limbs showed signs of moderate to severe arthritis. The therapeutic efficacy of anti-TNF-α antibody was assessed using various pathological indicators of disease progression. The clinical severity of arthritis in Tg197 mice was significantly reduced after anti-TNF-α treatment in comparison with saline-treated mice and in comparison with baseline assessments in both young and aged mice. The treatment with anti-TNF-α prevented loss of body weight. Inflammatory pathways as reflected by elevated circulating hTNF-α and local expression of various proinflammatory mediators were all diminished by anti-TNF-α treatment, confirming a critical role of hTNF-α in this model of progressive polyarthritis. More importantly, the amelioration of the disease was associated with reversal of existing structural damage, including synovitis and periosteal bone erosions evident on histology. Repair of cartilage was age dependent: reversal of cartilage degradation after anti-TNF-α treatment was observed in young mice but not in aged mice

    Direct Recognition of Fusobacterium nucleatum by the NK Cell Natural Cytotoxicity Receptor NKp46 Aggravates Periodontal Disease

    Get PDF
    Periodontitis is a common human chronic inflammatory disease that results in the destruction of the tooth attachment apparatus and tooth loss. Although infections with periopathogenic bacteria such as Porphyromonas gingivalis (P. gingivalis) and Fusobacterium nucleatum (F. nucleatum) are essential for inducing periodontitis, the nature and magnitude of the disease is determined by the host's immune response. Here, we investigate the role played by the NK killer receptor NKp46 (NCR1 in mice), in the pathogenesis of periodontitis. Using an oral infection periodontitis model we demonstrate that following F. nucleatum infection no alveolar bone loss is observed in mice deficient for NCR1 expression, whereas around 20% bone loss is observed in wild type mice and in mice infected with P. gingivalis. By using subcutaneous chambers inoculated with F. nucleatum we demonstrate that immune cells, including NK cells, rapidly accumulate in the chambers and that this leads to a fast and transient, NCR1-dependant TNF-α secretion. We further show that both the mouse NCR1 and the human NKp46 bind directly to F. nucleatum and we demonstrate that this binding is sensitive to heat, to proteinase K and to pronase treatments. Finally, we show in vitro that the interaction of NK cells with F. nucleatum leads to an NCR1-dependent secretion of TNF-α. Thus, the present study provides the first evidence that NCR1 and NKp46 directly recognize a periodontal pathogen and that this interaction influences the outcome of F. nucleatum-mediated periodontitis

    The provocative lumbar facet joint

    Get PDF
    Low back pain is the most common pain symptom experienced by American adults and is the second most common reason for primary care physician visits. There are many structures in the lumbar spine that can serve as pain generators and often the etiology of low back pain is multifactorial. However, the facet joint has been increasingly recognized as an important cause of low back pain. Facet joint pain can be diagnosed with local anesthetic blocks of the medial branches or of the facet joints themselves. Subsequent radiofrequency lesioning of the medial branches can provide more long-term pain relief. Despite some of the pitfalls associated with facet joint blocks, they have been shown to be valid, safe, and reliable as a diagnostic tool. Medial branch denervation has shown some promise for the sustained control of lumbar facet joint-mediated pain, but at this time, there is insufficient evidence that it is a wholly efficacious treatment option. Developing a universal algorithm for evaluating facet joint-mediated pain and standard procedural techniques may facilitate the performance of larger outcome studies. This review article provides an overview of the anatomy, pathophysiology, diagnosis, and treatment of facet joint-mediated pain

    Efficacy and safety of alirocumab in reducing lipids and cardiovascular events.

    Get PDF

    Header for SPIE use Design of a Gradient-Index Beam Shaping System via a Genetic Algorithm Optimization Method

    No full text
    Geometrical optics- the laws of reflection and refraction, ray tracing, conservation of energy within a bundle of rays, and the condition of constant optical path length- provides a foundation for design of laser beam shaping systems. This paper explores the use of machine learning techniques, concentrating on genetic algorithms, to design laser beam shaping systems using geometrical optics. Specifically, a three-element GRIN laser beam shaping system has been designed to expand and transform a Gaussian input beam profile into one with a uniform irradiance profile. Solution to this problem involves the constrained optimization of a merit function involving a mix of discrete and continuous parameters. The merit function involves terms that measure the deviation of the output beam diameter, divergence, and irradiance from target values. The continuous parameters include the distances between the lens elements, the thickness, and radii of the lens elements. The discrete parameters include the GRIN glass types from a manufacturer's database, the gradient direction of the GRIN elements (positive or negative), and the actual number of lens elements in the system (one to four)
    corecore